| Technical
Information for Hirers |
Theatre
Specifications | Orchestra Pits | Theatre
Equipment Performance | Electrics | Lamp
Stock | Rigging Access
Dimmer Packs and Cables | Public
Address Sound System | Cinema
Facilities | 35 mm Projection Equipment
Data Projection Equipment | Cinema
Sound System | Cinema Screen | Load Facilities | Dressing Room Complex |
| Theatre Specifications |
Seating Capacity |
B.N.Z Circle |
733 |
|
Stalls |
1097 (including 4 wheelchair spaces) |
|
Total |
1830 |
|
Stalls rows X, Y and
Z can be removed in multiples of three (as per seating
plan) for lighting and/or sound consoles if required.
Front stall seats can be removed with an approximate seating
loss of 300. |
|
Measurements |
Metres |
![Layout [536 kb PDF]](images/theatre01.jpg) |
Width of stage, wall to wall: |
26.300 |
Width of proscenium opening |
12.300 |
Height of proscenium opening |
8 |
Wing Space O.P. |
8.100 |
Wing Space P. |
5.900 |
Depth of stage, House rag to back
wall |
13.500 |
Depth of apron from centre |
2.850 |
Height under fly galleries |
8 |
Height from stage to grid |
19 |
Number of hand lines |
12 |
Number of counter weights |
24 |
No rake on the stage |
|
2 x 1 ton Chain Hoists |
1 metre out from Apron (Front of
House truss) |
Distance from Spot Box to Stage |
28.200 |
|
|
|
Distance from centre of Balcony
to Stage |
12.500 |
|
|
|
| |
|
|
|
|
| To view seating plans (pdf): |
Circle |
Stalls |
|
|
| Download PDF Reader here |
|
|
|
|
| |
|
|
|
|
|
| -Orchestra
Pits |
The outer pit accommodates 16 musicians.
With the apron lowered, it accommodates approximately 40 musicians. The outer pit is 1.850 metres (with the
loss of Row A seating). The cost of raising or lowering the
pit is to be agreed with the Technical Manager no later than
3 days prior to arrival in the theatre. |
| -Theatre
Equipment Performance |
The Regent Theatre endorses the “Guide
for Safe Working Practices in the New Zealand Theatre & Entertainment
Industry” and operates in accordance with them. To read this
document please refer to www.evanz.co.nz |
Black
tabs |
3 sets |
|
Black
legs |
7 sets |
|
Black
borders |
5 sets |
|
Cyclorama |
1 |
|
Tri Truss |
4 sections at 2.500m each |
|
2 loomed
house LX bars |
30 ac outlets each |
|
|
| -Electrics |
Power up to173 KVA load is available.
Additional power can be arranged at an agreed additional
cost to the hirer. |
AC
outlets |
20 dome |
|
|
50 Circle rail |
|
|
40 P.S. fly gallery |
|
|
12 O.P. fly gallery |
|
|
7 Stage dip boxes with 4 outlets
in each total of 28 |
|
63 amp Cee Form outlet up stage
prompt |
x2 |
|
20 outlets to the F.O.H truss |
|
|
Power outlet for tails available
at stage level |
|
|
| -Lamps |
|
2 x 1200 MSR Selecon
performer followspots |
|
|
12 x 2k Zoom Spots (Fixed in Dome) |
|
|
6 x 1k T 84 Zoom Spots 15/28 degrees |
|
|
20 x 2k S.F.
2000 (8" frame)
8/40 degrees |
|
|
3 x IRIS 4s Cyc Lights |
|
|
|
|
8 x 800/500w Cyc Lights |
|
|
12 x 650w Zoom Spots 16/30 degrees |
|
|
29 x 1k Pacific zoomspot 12/28
degree 18x gobo holders 12x iris |
|
48 x 1.2k Selecon Fresnel 8/58
degrees with barn doors |
|
39 par 64 CP61 filament (refer
section 2 Hire) |
|
Strand 520! Lighting console with
an R120 remote riggers control |
|
Theatrelight DMX link console with
house lights. |
|
|
Note: our stock of lamps is being increased
from time to time. Further lamps may be hired in if sufficient
notice is given. |
|
A Genie EWP capable of reaching up
to a 10.8m working height |
|
| |
10 channel 2k Theatrelight TL1010
series 2 |
|
| |
20 channel 5k Theatrelight TL5050
series 2 |
|
| |
5 LSC digital 12 packs |
|
|
|
| |
7 x Theatrelight 12 pack dimmers |
|
|
|
| |
1 x Theatrelight 12 pack digital
dimmer rack |
|
|
|
| |
1 x analogue to DMX512 converters. |
|
|
|
| |
Assorted extension cables |
|
|
|
| |
4 x 5 way LX loom 15mtr |
|
|
|
| |
16 x 5 way LX loom 30mtr |
|
|
|
| |
12 x 5 way LX multi 30mtr |
|
|
|
|
-Public
Address Sound System (not suitable for performance) |
300 watt SPX8 with twin tape suitable
for smaller functions and conferences.
There is an extra cost per performance or meeting for the use of this PA |
-CINEMA
FACILITIES (Upgraded in 2004) |
These high quality facilities are for
hire. Costs are negotiable. |
35mm
Projection Equipment |
Two Simplex 35mm PR1060A3
Projectors with ISCO Ultra Star optics |
Data
Projection Equipment |
Panasonic PT-L6500E
varied format Projector |
Cinema
Sound System
(not
available for live performances) |
Digital Dolby CP650 Cinema processor |
|
3 – Martin CMX2A screen 5 loud
speakers |
|
1 – MA4.2 amplifier |
|
|
|
|
6 –Martin sub screen speakers |
|
|
|
|
3 – Martin screen 5b speakers |
|
|
|
|
24 – Jands TH10 Surround speakers |
|
|
|
Cinema
Screen |
Harkness Perlux 2 |
|
|
|
|
|
The truck loading dock is situated
is through the Moray Place DCC public car park. Prior arrangement
with the Technical Mis required to book this facility. |
| |
Width of dock opening
2.6 metres |
| |
Dock Height 3.4 metres |
|
|
PLEASE NOTE No
vehicles may be parked in the stage door laneway area.
The nearest available parking to the theatre is in an adjacent
“Pay & Display” DCC
car park. Please discuss your unloading and parking requirements
with the Technical Manager before arriving at the Regent
Theatre. |
-The
Dressing Room Complex |
A Tannoy stage call system is installed
in this area. All dressing rooms contain showers, toilets
and hand basins.
|
| |
5 dressing rooms are
located at stage level (maximum 4 persons each). |
| |
3 dressing rooms are
located on the 1st floor (approximately 20 persons each). |
|
A kitchen and Green Room are available
for use on the 1st floor.
A wardrobe area with laundry, drying facilities and an iron and ironing board
are available for use in the basement.
Additional charges will apply if cleaning
requirements involve removing stains (body paint, make-up etc) and/or repairing
damage to property. The Hirer and Theatre Management shall
come to agreement about any such charges prior to settlement
of the account. |
Please contact our Technical
Manager for any additional information you need to do with
your backstage requirements.
Phone: (064) 03 477 6481 or mobile 0274 355 803
Email: nelsonm@regenttheatre.co.nz
Please ensure you are in agreement with
him on all related matters prior to the commencement of your
first performance in the Regent Theatre.
Regent Theatre Layout [536kb] PDF |
|
 |
 |
 |
Click
on each image for a larger scale version
of the evacuation
plans. |